Products and Services


Precise Controlled Atmosphere Glove Boxes

Source: Labconco Corporation
Precise Controlled Atmosphere Glove Boxes provide a leak-tight environment for work with contamination-sensitive materials. Procedures where low levels of oxygen or moisture are important, such as work with organometallics; alternative energy cells; or hydrophilic chemicals, are typical applications for these economical glove boxes.
Details

Precise Controlled Atmosphere Glove Boxes provide a leak-tight environment for work with contamination-sensitive materials. Procedures where low levels of oxygen or moisture are important, such as work with organometallics; alternative energy cells; or hydrophilic chemicals, are typical applications for these economical glove boxes.

Features

  • One-piece molded, medium-density polyethylene shell.
  • Dry powder epoxy-coated steel superstructure
  • 1/4" thick laminated safety glass viewing window, 26.4" wide x 12.5" high, removable for loading equipment, with powder-coated steel frame and neoprene gasket
  • Space-saving inner and outer transfer chamber doors that pivot upward, are counterbalanced and equipped with quick-latches
  • Black, chemical-resistant work surface sealed to the glove box floor
  • Pressure relief valve that activates at pressure/vacuum above 6 inches or below -6 inches of water gauge.
  • Pressure relief valve vent, 4" nominal diameter
  • Interior ceiling-mounted electrical duplex receptacle with 5 amp maximum circuit load
  • Neoprene gloves, size 9 3/4, are included.
  • Fluorescent lamp, 22 watts, with easy replacement from the top
  • Switches for light and innermost interior electrical receptacle
  • Approximately 13 cubic feet of interior space in main chamber
  • 11.0" nominal ID x 12.0" long transfer chamber
  • Factory leak tested with a mass spectrometer while glove box is pressurized with helium at 5 inches of water gauge.
  • No detectable leaks greater than 1 x 10(-4) ml/sec
  • Meet Class 1 atmosphere containment conditions for oxygen leak rates per ISO 10648-2 test method
  • Six manual valves for purging and filling of both main chamber and transfer chamber and for drying train connections
  • Main chamber pressure gauge with readings from -5 to +5 inches of water gauge
  • Transfer chamber pressure gauge with readings from 0 to -29 inches of mercury
  • Transfer chamber high vacuum sleeve and interior interlocking shelf of dry powder epoxy-coated steel
  • ETL listed (115 volt models)
  • CE Conformity (230 volt models)
  • Most Popular

    Need Information?

    Please wait... busy