White Paper: Cleaning Study Of Glatt Coating Pan Containing Eudragit NE30D Polymer
The primary objectives of this cleaning study were to ascertain the feasibility of conducting automated Cleaning-In-Place (CIP) of an R&D Glatt coating pan and to prove that the CIP cleaning concept was truly an automated, repeatable process.
The cleaning study included preliminary cleaning trials that clearly showed that it is feasible to automatically clean the coating pan and the associated transfer lines with a MORK CIP system and a spray device setup.
The cleaning study clearly showed that it is feasible to automatically clean the Glatt XC 1500 coating pan with only a low-pressure CIP system (< 100 psi). The trial was performed after an under filled / overspray condition was processed – utilizing a setup consisting of the following:
- One MORK Mobile CIP Unit
- Flexible hoses
- One CIP nozzle
- Transfer piping loop.