Capture, Transmit, And Produce More Ions With The Triple Quad 6500+ System

triple quad 6500

Revolutionary sensitivity, speed, and performance with IonDrive technology

The Triple Quad 6500+ system features multi-component IonDrive technology including the IonDrive High Energy Detector+ that pushes the boundaries of LC-MS/MS quantification farther than ever before. The revolutionary sensitivity, speed, and performance delivered through these technology enhancements enable you to see it all, from low mass to high mass compounds, in positive or negative polarity – in a single injection, with high sensitivity, reliability, and confidence.

  • Superior signal-to-noise and LOQ for the widest scope of chemical compounds in the most challenging matrices

  • Up to 6 orders of linear dynamic range for an enhanced breadth of applications

  • Increased throughput with polarity switching speeds of 5 msec

  • No compromise in mass range with a 2000 m/z upper mass limit

  • Scan speeds of up to 12,000 Da/second for optimized UHPLC strategies

  • Compatible with SelexION+ differential mobility spectometry

  • Enhanced ion transmission for added selectivity without compromising LOQs

The Triple Quad 6500+ system delivers revolutionary sensitivity, speed, and performance for your most challenging methods.

Key Features

  • Mass range: Triple quadrupole: 5 – 2,000 Da

  • Flexible ionization options: Options include OptiFlow Turbo V Electrospray ionization (ESI) and heated nebulizer ionization probes.

  • Selective, robust and powerful ion separation: Optional SelexION+ differential mobility spectrometry

  • Detector type: IonDrive High Energy Detector+

  • Polarity switching: 5 msec in MRM and Scheduled MRM modes

Enhancements for the 6500+ series

The production of more ions with the IonDrive Turbo V source is just one of the enhancements you will see with the Triple Quad 6500+ system. Also added is the ability to capture and transmit more ions with the unique IonDrive QJet guide and greater detection with the new IonDrive High Energy Detector+.

IonDrive Turbo V ion source

The legendary Turbo V source increases ion production by using enhanced gas flow dynamics and optimized heater configuration to improve reliability, reproducibility, and robustness

IonDrive QJet ion guide

With its dual-stage design, the IonDrive QJet ion guide improves sensitivity and ion capture rate while focusing ions more efficiently than funnel approaches.

IonDrive High Energy Detector+

Pulse counting fundamentals achieve ultra sensitivity at the lower end, while increasing linearity at high count rates. The result is the collection of more ions across a broader dynamic range.

SelexION+ DMS technology

Ideal development suite for applications requiring the separation of isobaric species, isolation of challenging co-eluting contaminants, and reduction of high background noise.